Calculate the AC energy before pricing it
Find electrical input power from the exact air-conditioner label or monitoring record. Cooling capacity in tons or BTU/h is not the same as electrical input. Multiply input kilowatts by operating hours and a measured or explicitly tested operating factor to estimate kWh.
For variable-speed equipment, a plug or circuit energy record over representative hot days is usually more useful than assuming the compressor draws nameplate power continuously.
Add the energy to the existing billing month
A progressive slab calculation depends on the household's total monthly electricity, not the AC in isolation. Begin with the expected non-AC consumption, then add the AC kWh. The added units may sit partly in one slab and partly in the next.
Use the same billing period and account type as the DEWA bill. Water consumption is a separate input in the combined calculator and should not be inferred from cooling use.
Keep the bill month and units current
The calculator defaults to DEWA's August 2026 electricity and water fuel surcharges. Replace both for another bill month. Water has been billed in cubic metres since the March 2025 cycle, so do not paste an old imperial-gallon figure into the current workflow.
The tool adds selected meter-service charges and calculates five percent VAT on the displayed taxable subtotal. Housing, sewerage, deposits, arrears and other VAT-exempt or account-specific lines remain separate unless copied into the dedicated field.
- Verify account category and billing dates.
- Use cubic metres for current water bills.
- Keep base slabs, fuel surcharge, meter service, VAT and exempt lines separate.
Compare changes with the same comfort target
To test a thermostat, schedule or replacement unit, hold room, occupancy and comfort assumptions as consistent as possible. Compare measured kWh across similar weather or use a labelled scenario range. A lower daily runtime on a mild week is not proof of an equipment saving.
The result is a bill-planning scenario, not a diagnosis of an AC system. Maintenance, sizing and electrical work require qualified local professionals.
Worked example: extra cooling energy
Inputs
- Existing monthly electricity: 900 kWh
- AC input: 1.5 kW
- Illustrative equivalent runtime: 4 hours/day for 30 days
- Current DEWA slab rates and surcharge to be entered by the user
Working
- AC energy = 1.5 × 4 × 30 = 180 kWh
- New household total = 900 + 180 = 1,080 kWh
- Allocate the 1,080 kWh across the current entered slabs, then compare with the original 900 kWh scenario
Sources for this guide
Slab tariff
Dubai Electricity and Water Authority
Current Dubai electricity and water slab thresholds and rates.
Open official resourceValue Added Tax on DEWA bills
Dubai Electricity and Water Authority
Official explanation of which DEWA bill components attract five percent VAT.
Open official resourceWater billing adopts cubic metres
Dubai Electricity and Water Authority
Official notice that Dubai water billing changed from imperial gallons to cubic metres from March 2025.
Open official resourceConsumption verification
Dubai Electricity and Water Authority
Official guidance for checking electricity and water meter readings and consumption.
Open official resourceUnderstand your bill
Dubai Electricity and Water Authority
Official description of bill sections and charges.
Open official resource